Command Line Reference Guide
Changed interface state to down: Po 102
Apr 8 10:22:44: %STKUNIT3-M:CP %IFMGR-1-DEL_PORT: Removed
port: Te 4/0-3,16-47, Fo 4/48,52,60,
Apr 8 10:22:44: %STKUNIT3-M:CP %CHMGR-2-STACKUNIT_DOWN: Stack
unit 4 down - reset
Apr 8 10:22:44: %STKUNIT2-S:CP %IFMGR-1-DEL_PORT: Removed
port: Te 4/0-3,16-47, Fo 4/48,52,60,
Apr 8 10:22:50: %S5000:3 %IFAGT-5-STACK_PORT_LINK_DOWN:
Changed stack port state to down: 3/12
Related
Commands
• reload – reboots FTOS.
• upgrade system stack-unit – synchronizes the FTOS image running on an S5000 stack
unit from the master switch.
show redundancy
Display the current redundancy configuration (status of automatic reboot configuration on stack management unit).
S5000
Syntax
show redundancy
Command Modes
• EXEC
• EXEC Privilege
Command History
Version 9.0(1.3) Introduced on the S5000.
Example
FTOS#show redundancy
-- Stack-unit Status --
------------------------------------------------
Mgmt ID: 0
Stack-unit ID: 4
Stack-unit Redundancy Role: Primary
Stack-unit State: Active
Stack-unit SW Version: 9.0(1.3)
Link to Peer: Up
-- PEER Stack-unit Status --
------------------------------------------------
Stack-unit State: Standby
Peer stack-unit ID: 3
Stack-unit SW Version: 9.0(1.0)
-- Stack-unit Redundancy Configuration --
------------------------------------------------
Primary Stack-unit: mgmt-id 0
Auto Data Sync: Full
Failover Type: Hot Failover
Auto reboot Stack-unit: Disabled
Auto failover limit: 3 times in 60 minutes
1233