Command Line Reference Guide
redundancy force-failover stack-unit
Force the standby unit in the stack to become the management unit.
S5000
Syntax
redundancy force-failover stack-unit
Defaults Not enabled.
Command Modes EXEC Privilege
Command History
Version 9.0(1.3) Introduced on the S5000.
reset stack-unit
Reset any designated stack member except the management unit (master unit).
S5000
Syntax
reset stack-unit unit-number hard
Parameters
unit-number
Enter the stack-unit number. The range is 0 to 11.
hard Reset the stack unit if the unit is in a problem state.
Defaults none
Command Modes EXEC
Command History
Version 9.0(1.3) Introduced on the S5000.
Usage
Information
Resetting the management unit is not allowed, and an error message displays if you try to do
so. Resetting is a soft reboot, including flushing the forwarding tables.
You can run this command directly on the stack standby unit (standby master) to reset the
standby. You cannot reset any other unit from the standby unit.
Example
FTOS#reset stack-unit 4
Apr 8 10:22:43: %STKUNIT3-M:CP %CHMGR-5-STACKUNIT_RESET: Stack
unit 4 being reset
Apr 8 10:22:43: %STKUNIT3-M:CP %IFMGR-5-OSTATE_DN: Changed
interface state to down: Te 4/0
Apr 8 10:22:43: %STKUNIT3-M:CP %IFMGR-5-OSTATE_DN: Changed
interface state to down: Te 4/20
Apr 8 10:22:43: %STKUNIT3-M:CP %IFMGR-5-OSTATE_DN: Changed
interface state to down: Te 4/21
Apr 8 10:22:44: %STKUNIT3-M:CP %IFMGR-5-OSTATE_DN: Changed
interface state to down: Te 4/22
Apr 8 10:22:44: %STKUNIT3-M:CP %IFMGR-5-OSTATE_DN: Changed
interface state to down: Te 4/23
FTOS#Apr 8 10:22:44: %STKUNIT3-M:CP %IFMGR-5-OSTATE_DN:
1232