Command Line Reference Guide
Command History
Version 9.0(1.3) Introduced on the S5000.
Usage
Information
When you use the no logging on command, messages are logged only to the console.
Related
Commands
logging – enables logging to the Syslog server.
logging buffered – sets the logging buffered parameters.
logging console – sets the logging console parameters.
logging monitor – sets the logging parameters for the terminal connections.
logging source-interface
Specify that the IP address of an interface is the source IP address of Syslog packets sent to the Syslog server.
S5000
Syntax
logging source-interface interface
To disable this command and return to the default setting, use the no logging source-
interface
command.
Parameters
interface
Enter the following keywords and slot/port or number information:
• For a Gigabit Ethernet interface, enter the keyword
GigabitEthernet followed by the slot/port information.
• For a 10-Gigabit Ethernet interface, enter the keyword
TenGigabitEthernet followed by the slot/port
information.
• For a 40-Gigabit Ethernet interface, enter the keyword
fortyGigE followed by the slot/port information.
• For Loopback interfaces, enter the keyword loopback
followed by a number from zero (0) to 16383.
• For the management interface, enter the keyword
ManagementEthernet followed by the slot/port
information. The slot range is 0 to 1 and the port range is 0.
• For a Port Channel interface, enter the keywords port-
channel followed by a number. The range is 1 to 128.
• For VLAN interface, enter the keyword vlan followed by a
number from 1 to 4094.
Defaults Not configured.
Command Modes CONFIGURATION
Command History
Version 9.0(1.3) Introduced on the S5000.
1214