Command Line Reference Guide

Parameters
interface
type
slot/port
(OPTIONAL) Enter the interface keyword followed by the
interface type and slot/port or number information. Valid slot numbers
are 0-11. The valid port numbers for each interface type are listed
below.
For a 10-Gigabit Ethernet interface, enter the keyword
tengigabitethernet followed by slot/port numbers.
The port range is 0 to 63.
For a 40-Gigabit Ethernet interface, enter the keyword
fortyGigE followed by slot/port numbers. The ports are 48,
52, 56, and 60.
For a Port Channel interface, enter the keywords port-
channel
followed by a number from 1 to 128.
Command Modes
EXEC
EXEC Privilege
Command History
Version 9.0(1.3) Introduced on the S5000.
Usage
Information
The dropEvent counter (sFlow samples dropped due to sub-sampling) shown in the Example
below always displays a value of zero.
Example
FTOS#show sflow
sFlow services are enabled
Global default sampling rate: 32768
Global default counter polling interval: 20
1 collectors configured
Collector IP addr: 133.33.33.53, Agent IP addr: 133.33.33.116,
UDP port: 6343
0 UDP packets exported
0 UDP packets dropped
165 sFlow samples collected
0 sFlow samples dropped due to sub-sampling
Stack-unit 1 Port set 0 H/W sampling rate 8192
Te 1/16: configured rate 8192, actual rate 8192, sub-
sampling rate 1
Te 1/17: configured rate 16384, actual rate 16384, sub-
sampling rate 2
Stack-unit 3 Port set 1 H/W sampling rate 16384
Te 3/40: configured rate 16384, actual rate 16384, sub-
sampling rate 1
FTOS#
1187