Command Line Reference Guide
Related
Commands
sflow polling-interval (Interface) – sets the polling interval for an interface.
sflow polling-interval (Interface)
Set the sFlow polling interval at an interface (overrides the global-level setting.)
S5000
Syntax
sflow polling-interval interval value
To return to the default, use the no sflow polling-interval interval command.
Parameters
interval value
Enter the interval value in seconds. The range is 15 to 86400 seconds.
The default is the global counter polling interval.
Defaults The same value as the current global default counter polling interval.
Command Modes INTERFACE
Command History
Version 9.0(1.3) Introduced on the S5000.
Usage
Information
This command sets the counter polling interval for an interface.
Related
Commands
sflow polling-interval (Global) – globally sets the polling interval.
sflow sample-rate (Global)
Change the global default sampling rate.
S5000
Syntax
sflow sample-rate value
To return to the default sampling rate, use the no sflow sample-rate command.
Parameters
value
Enter the sampling rate value. The range is 256 to 8388608 packets.
Defaults 32768 packets
Command Modes CONFIGURATION
Command History
Version 9.0(1.3) Introduced on the S5000.
1185