Command Line Reference Guide

alarm status: OK
FTOS#
Example (Brief)
FTOS#show rmon hc-alarm brief
index SNMP OID
----------------------------------
1 1.3.6.1.2.1.1.3
2 1.3.6.1.2.1.1.3
3 1.3.6.1.2.1.1.3
4 1.3.6.1.2.1.1.3
5 1.3.6.1.2.1.1.3
FTOS#
show rmon history
Display the contents of the RMON Ethernet history table.
S5000
Syntax
show rmon history [index] [brief]
Parameters
index
(OPTIONAL) Enter the table index number to display just that entry.
brief (OPTIONAL) Enter the keyword brief to display the RMON Ethernet
history table in an easy-to-read format
Defaults none
Command Modes EXEC
Command History
Version 9.0(1.3) Introduced on the S5000.
Example (Index)
FTOS#show rmon history 6001
RMON history control entry 6001
interface: ifIndex.100974631 TenGigabitEthernet 2/0
bucket requested: 1
bucket granted: 1
sampling interval: 5 sec
owner: 1
status: OK
FTOS#
Example (Brief)
FTOS#show rmon history brief
index ifIndex interface
---------------------------------------
6001 100974631 TenGigabitEthernet 2/0
6002 100974631 TenGigabitEthernet 2/0
6003 101236775 TenGigabitEthernet 2/1
6004 101236775 TenGigabitEthernet 2/1
9001 134529054 TenGigabitEthernet 3/0
9002 134529054 TenGigabitEthernet 3/0
9003 134791198 TenGigabitEthernet 3/1
1105