Command Line Reference Guide
owner
name
(OPTIONAL) Enter the keyword owner followed by the owner name
to record the owner of the RMON group of statistics.
buckets
number
(OPTIONAL) Enter the keyword buckets followed the number of
buckets for the RMON collection history group of statistics. The
bucket range is 1 to 1000. The default is
50.
interval
seconds
(OPTIONAL) Enter the keyword interval followed the number of
seconds in each polling cycle. The range is 5 to 3600 seconds. The
default is 1800 seconds.
Defaults none
Command Modes CONFIGURATION INTERFACE (config-if)
Command History
Version 9.0(1.3) Introduced on the S5000.
rmon collection statistics
Enable RMON MIB statistics collection on an interface.
S5000
Syntax
rmon collection statistics {controlEntry integer} [owner name]
To remove RMON MIB statistics collection on an interface, use the no rmon collection
statistics {controlEntry integer} command.
Parameters
controlEntry
integer
Enter the keyword controlEntry to specify the RMON group of
statistics using a value. Then enter an integer value from 1 to 65535
that identifies the RMON Statistic Table. The integer value must be a
unique in the RMON statistic table.
owner
name
(OPTIONAL) Enter the keyword owner followed by the owner name
to record the owner of the RMON group of statistics.
Defaults none
Command Modes CONFIGURATION INTERFACE (config-if)
Command History
Version 9.0(1.3) Introduced on the S5000.
1099