Users Guide

-- Stack Info --
Unit UnitType Status ReqTyp CurTyp Version Ports
-----------------------------------------------------------------------------------
-
1 Member not present
2 Management online S3148P S3148P 1-0(0-4679) 54
3 Standby online S3148P S3148P 1-0(0-4679) 54
4 Member not present
5 Member not present
6 Member not present
7 Member not present
8 Member not present
9 Member not present
10 Member not present
11 Member not present
12 Member not present
-- Module Info --
Unit Module No Status Module Type Ports
---------------------------------------------------------------------------
2 1 online S3148P-10GE-2SFP+ 2
3 1 online S3148P-10GE-2X10BaseT 2
-- Power Supplies --
Unit Bay Status Type FanStatus FanSpeed(rpm)
---------------------------------------------------------------------------
2 1 up AC up NA
2 2 absent absent NA
3 1 absent absent 0
3 2 up AC up 7888
-- Fan Status --
Unit Bay TrayStatus Fan1 Speed Fan2 Speed
-----------------------------------------------------------------------------------
-
2 1 up up 6956 up 7058
3 1 up up 7058 up 7164
Speed in RPM
Dell#
Troubleshoot a Stack
To troubleshoot a stack, use the following recovery tasks.
Recover from Stack Link Flaps
Recover from a Card Problem State on a Stack
Recover from Stack Link Flaps
Stack link integrity monitoring enables units to monitor their own stack ports and disable any stack port that
flaps five times within 10 seconds.
Dell Networking OS displays console messages for the local and remote members of a flapping link, and on
the primary (master) and standby management units as KERN-2-INT messages if the flapping port belongs to
either of these units.
Stacking 951