CLI Guide
clock timezone
Configure a timezone for the switch.
Syntax
clock timezone timezone-name offset
To delete a timezone configuration, use the no clock timezone command.
Parameters
timezone-name Enter the name of the timezone. You cannot use spaces.
offset Enter one of the following:
• a number from 1 to 23 as the number of hours in
addition to universal time coordinated (UTC) for the
timezone.
• a minus sign (-) then a number from 1 to 23 as the
number of hours.
Defaults Not configured.
Command Modes CONFIGURATION
Command History
This guide is platform-specific. For command information about other platforms,
see the relevant Dell Networking OS Command Line Reference Guide.
Version Description
9.8(2.0) Introduced on the S3100 series.
9.8(0.0P5) Introduced on the S4048-ON.
9.8(0.0P2) Introduced on the S3048-ON.
9.7(0.0) Introduced on the S6000-ON.
9.2(1.0) Introduced on the Z9500.
9.0.2.0 Introduced on the S6000.
8.3.19.0 Introduced on the S4820T.
8.3.11.1 Introduced on the Z9000.
8.3.7.0 Introduced on the S4810.
7.6.1.0 Introduced on the S-Series.
7.5.1.0 Introduced on the C-Series.
6.1.1.0 Introduced on the E-Series.
Usage Information Coordinated universal time (UTC) is the time standard based on the International
Atomic Time standard, commonly known as Greenwich Mean time. When
determining system time, include the differentiator between UTC and your local
timezone. For example, San Jose, CA is the Pacific Timezone with a UTC offset of
-8.
1754
System Time and Date