CLI Guide
• xstp — Enable 802.1s, 802.1w, and PVST+ state change
traps
The default is all trap types are sent to host.
Defaults As above.
Command Modes CONFIGURATION
Command History
This guide is platform-specific. For command information about other platforms,
see the relevant Dell Networking OS Command Line Reference Guide.
Version Description
9.8(2.0) Introduced on the S3100 series.
9.8(0.0P5) Introduced on the S4048-ON.
9.8(0.0P2) Introduced on the S3048-ON.
9.7(0.0) Introduced on the S6000-ON.
9.4.(0.0) Added support for VRF.
9.2(1.0) Introduced on the Z9500.
9.0.2.0 Introduced on the S6000.
9.1(0.0) Added support for config and ecmp traps.
8.3.19.0 Introduced on the S4820T.
8.3.11.1 Introduced on the Z9000.
8.3.7.0 Introduced on the S4810.
8.4.1.0 Added support for VRRP traps.
7.6.1.0 Added support for STP and xSTP notification types.
Introduced on the S-Series.
7.5.1.0 Introduced on the C-Series.
E-Series legacy
command
Usage Information
To configure the router to send SNMP notifications, enter at least one snmp-
server host command. If you enter the command with no keywords, all trap
types are enabled for the host. If you do not enter an
snmp-server host
command, no notifications are sent.
In order to enable multiple hosts, issue a separate snmp-server host command
for each host. You can specify multiple notification types in the command for each
host.
When multiple snmp-server host commands are given for the same host and
type of notification (trap or inform), each succeeding command overwrites the
1670
Simple Network Management Protocol (SNMP) and Syslog