CLI Guide
Version Description
8.3.11.1 Introduced on the Z9000.
8.3.7.0 Introduced on the S4810.
8.2.1.0 Introduced on S-Series Stacking.
8.1.1.0 Introduced on the E-Series.
7.7.1.0 Introduced on the S-Series.
7.6.1.0 Introduced on the C-Series.
7.4.1.0 Introduced on the E-Series.
Usage Information The polling interval for an interface is the maximum number of seconds between
successive samples of counters sent to the collector. This command changes the
global default counter polling (20 seconds) interval. You can configure an interface
to use a different polling interval.
Related
Commands
• sflow polling-interval (Interface) — sets the polling interval for an interface.
sflow polling-interval (Interface)
Set the sFlow polling interval at an interface (overrides the global-level setting.)
Syntax
sflow polling-interval interval value
To return to the default, use the no sflow polling-interval interval
command.
Parameters
interval value Enter the interval value in seconds. The range is from 15 to
86400 seconds. The default is the global counter polling
interval.
Defaults The same value as the current global default counter polling interval.
Command Modes INTERFACE
Command History
This guide is platform-specific. For command information about other platforms,
see the relevant Dell Networking OS Command Line Reference Guide.
Version Description
9.8(2.0) Introduced on the S3100 series.
9.8(0.0P5) Introduced on the S4048-ON.
9.8(0.0P2) Introduced on the S3048-ON.
9.7(0.0) Introduced on the S6000-ON.
1648
sFlow