CLI Guide
switchport mode private-vlan
Set PVLAN mode of the selected port.
Syntax
[no] switchport mode private-vlan {host | promiscuous | trunk}
To remove PVLAN mode from the selected port, use the no switchport mode
private-vlan command.
Parameters
host Enter the keyword host to configure the selected port or
port channel as an isolated interface in a PVLAN.
promiscuous Enter the keyword promiscuous to configure the selected
port or port channel as an promiscuous interface.
trunk Enter the keyword trunk to configure the selected port or
port channel as a trunk port in a PVLAN.
Defaults Disabled.
Command Modes INTERFACE
Command History
This guide is platform-specific. For command information about other platforms,
see the relevant Dell Networking OS Command Line Reference Guide.
Version Description
9.8(2.0) Introduced on the S3100 series.
9.8(0.0P5) Introduced on the S4048-ON.
9.8(0.0P2) Introduced on the S3048-ON.
9.7(0.0) Introduced on the S6000-ON.
9.2(1.0) Introduced on the Z9500.
9.0.2.0 Introduced on the S6000.
8.3.19.0 Introduced on the S4820T.
8.3.11.1 Introduced on the Z9000.
8.3.7.0 Introduced on the S4810.
7.8.1.0 Introduced on the C-Series and S-Series.
Usage Information
The assignment of the various PVLAN port types to port and port channel (LAG)
interfaces is shown in the following example.
Example
Dell# conf
Dell(conf)# interface GigabitEthernet 2/1
Dell(conf-if-gi-2/1)# switchport mode private-vlan promiscuous
1384
Private VLAN (PVLAN)