CLI Guide

Isolated port — an isolated port is a port that, in Layer 2, can only communicate with promiscuous
ports that are in the same PVLAN.
Promiscuous port — a promiscuous port is a port that is allowed to communicate with any other port
type.
Trunk port — a trunk port carries VLAN traffic across switches:
A trunk port in a PVLAN is always tagged.
A trunk port in Tagged mode carries primary or secondary VLAN traffic. The tag on the packet
helps identify the VLAN to which the packet belongs.
A trunk port can also belong to a regular VLAN (non-private VLAN).
ip local-proxy-arp
Enable/disable Layer 3 communication between secondary VLANs in a private VLAN.
Syntax
[no] ip local-proxy-arp
To disable Layer 3 communication between secondary VLANs in a private VLAN,
use the no ip local-proxy-arp command in INTERFACE VLAN mode for the
primary VLAN.
To disable Layer 3 communication in a particular secondary VLAN, use the no ip
local-proxy-arp command in INTERFACE VLAN mode for the selected
secondary VLAN.
NOTE: Even after you disable ip-local-proxy-arp (use no ip-local-
proxy-arp) in a secondary VLAN, Layer 3 communication may happen
between some secondary VLAN hosts, until the address resolution protocol
(ARP) timeout happens on those secondary VLAN hosts.
Defaults Layer 3 communication is disabled between secondary VLANs in a private VLAN.
Command Modes INTERFACE VLAN
Command History
This guide is platform-specific. For command information about other platforms,
see the relevant Dell Networking OS Command Line Reference Guide.
Version Description
9.8(2.0) Introduced on the S3100 series.
9.8(0.0P5) Introduced on the S4048-ON.
9.8(0.0P2) Introduced on the S3048-ON.
9.7(0.0) Introduced on the S6000-ON.
9.2(1.0) Introduced on the Z9500.
1380
Private VLAN (PVLAN)