Users Guide

Table Of Contents
Line Description
RS state This is the reserved digital state of the pin AS(1) per SFF-8079 and RS(1) per
SFF-8431.
Tx Disable state If the admin status of the port is down then this flag is set to true.
Temperature
High Alarm Flag
This can be either true or false, depending on the Current voltage value displayed
above.
Voltage High
Alarm Flag
This can be either true or false, depending on the Current Temperature value
displayed above.
Tx Bias High
Alarm Flag
This can be either true or false, depending on the present Tx bias current value
displayed above.
Tx Power High
Alarm Flag
This can be either true or false, depending on the Current Tx bias power value
displayed above.
Rx Power High
Alarm Flag
This can be either true or false, depending on the Current Rx power value displayed
above.
Temperature Low
Alarm Flag
This can be either true or false, depending on the Current Temperature value
displayed above.
Voltage Low
Alarm Flag
This can be either true or false, depending on the Current voltage value displayed
above.
Tx Bias Low
Alarm Flag
This can be either true or false, depending on the Tx bias current value displayed
above.
Tx Power Low
Alarm Flag
This can be either true or false, depending on the Current Tx power value displayed
above.
Rx Power Low
Alarm Flag
This can be either true or false, depending on the Current Rx power value displayed
above.
Temperature
High Warning
Flag
This can be either true or false, depending on the Current Temperature value
displayed above.
Voltage High
Warning Flag
This can be either true or false, depending on the Current Voltage value displayed
above.
Tx Bias High
Warning Flag
This can be either true or false, depending on the Tx bias current value displayed
above.
Tx Power High
Warning Flag
This can be either true or false, depending on the Current Tx power value displayed
above.
Rx Power High
Warning Flag
This can be either true or false, depending on the Current Tx power value displayed
above.
Temperature Low
Warning Flag
This can be either true or false, depending on the Current Temperature value
displayed above.
Voltage Low
Warning Flag
This can be either true or false, depending on the Current Voltage value displayed
above.
Tx Bias Low
Warning Flag
This can be either true or false, depending on the present Tx bias current value
displayed above.
Tx Power Low
Warning Flag
This can be either true or false, depending on the Current Tx power value displayed
above.
Rx Power Low
Warning Flag
This can be either true or false, depending on the Current Rx power value displayed
above.
Example
Dell# show interfaces GigabitEthernet 1/1 transceiver
SFP is present.
SFP 0 Serial Base ID fields
608 Interfaces