Users Guide

Table Of Contents
Related
Commands
show uplink-state-group displays the status information on a specified uplink-state group or all
groups.
uplink-state-group creates an uplink-state group and enables the tracking of upstream links.
show uplink-state-group
Display status information on a specified uplink-state group or all groups.
Syntax
show uplink-state-group [group-id] [detail]
Parameters
group-id
Displays status information on a specified uplink-state group or all groups. The valid
group-id values are from 1 to 16.
detail Displays additional status information on the upstream and downstream interfaces
in each group
Defaults none
Command Modes
EXEC
EXEC Privilege
Command
History
This guide is platform-specific. For command information about other platforms, see the relevant Dell
Networking OS Command Line Reference Guide.
Version Description
9.8(2.0) Introduced on the S3100 series.
9.8(0.0P5) Introduced on the S4048-ON.
9.8(0.0P2) Introduced on the S3048-ON.
9.2(1.0) Introduced on the Z9500.
9.2(0.0) Introduced on the M I/O Aggregator. This command is supported in Programmable-
Mux (PMUX) mode only.
8.3.19.0 Introduced on the S4820T.
8.3.12.0 Introduced on the S4810.
8.4.2.3 Introduced on the S-Series S50.
Example
Dell# show uplink-state-group
Uplink State Group: 1 Status: Enabled, Up
Uplink State Group: 3 Status: Enabled, Up
Uplink State Group: 5 Status: Enabled, Down
Uplink State Group: 6 Status: Enabled, Up
Uplink State Group: 7 Status: Enabled, Up
Uplink State Group: 16 Status: Disabled, Up
Dell# show uplink-state-group 16
Uplink State Group: 16 Status: Disabled, Up
Dell#show uplink-state-group detail
(Up): Interface up (Dwn): Interface down (Dis): Interface disabled
Uplink State Group : 1 Status: Enabled, Up
Upstream Interfaces :
Downstream Interfaces :
Uplink State Group : 3 Status: Enabled, Up
Upstream Interfaces : Gi 1/25(Up) Gi 1/28(Up)
Downstream Interfaces : Te 5/1(Up) Te 5/1(Up) Te 5/3(Up) Te 5/5(Up) Te
5/6(Up)
Uplink State Group : 5 Status: Enabled, Down
Upstream Interfaces : Gi 1/1(Dwn) Gi 1/3(Dwn) Gi 1/5(Dwn)
Downstream Interfaces : Te 5/2(Dis) Te 5/4(Dis) Te 5/11(Dis) Te
Uplink Failure Detection (UFD) 1421