Users Guide

Table Of Contents
Version Description
9.0.2.0 Introduced on the S6000.
8.3.19.0 Introduced on the S4820T.
8.3.11.1 Introduced on the Z9000.
8.3.7.0 Introduced on the S4810.
7.6.1.0 Introduced on the S-Series.
7.5.1.0 Introduced on the C-Series.
E-Series legacy
command
snmp-server enable traps
Enable SNMP traps.
Syntax
snmp-server enable traps [notification-type] [notification-option]
To disable traps, use the no snmp-server enable traps [notification-type]
[notification-option] command.
Parameters
notification-type
Enter the type of notification from the following list:
bgp Notification of changes in the BGP process.
config Notification of changes to the startup or running configuration.
ecfm Notification of changes to ECFM.
ecmp Enable an ECMP trap to notify of ECMP or link bundle traffic
imbalances.
envmon For Dell Networking device notifications when an environmental
threshold is exceeded.
isis Notification of intermediate service traps.
lacp Notification of changes.
snmp Notification of RFC 1157 traps.
stp Notification of a state change in the spanning tree protocol (RFC 1493).
vlt Notification of virtual link trunking.
vrrp Notification of a state change in a VRRP group.
xstp Notification of a state change in MSTP (802.1s), RSTP (802.1w), and
PVST+.
notification-
option
For the envmon notification-type, enter one of the following optional parameters:
cam-utilization
fan
supply
temperature
For the snmp notification-type, enter one of the following optional parameters:
authentication
coldstart
linkdown
linkup
syslog-reachable
syslog-unreachable
Defaults Not enabled.
Command Modes CONFIGURATION
1302 Simple Network Management Protocol (SNMP) and Syslog