Users Guide

Table Of Contents
sflow polling-interval (Interface)
Set the sFlow polling interval at an interface (overrides the global-level setting.)
Syntax
sflow polling-interval interval value
To return to the default, use the no sflow polling-interval interval command.
Parameters
interval value
Enter the interval value in seconds. The range is from 15 to 86400 seconds. The
default is the global counter polling interval.
Defaults The same value as the current global default counter polling interval.
Command Modes INTERFACE
Command
History
This guide is platform-specific. For command information about other platforms, see the relevant Dell
Networking OS Command Line Reference Guide.
Version Description
9.8(2.0) Introduced on the S3100 series.
9.8(1.0) Introduced on the Z9100-ON.
9.8(0.0P5) Introduced on the S4048-ON.
9.8(0.0P2) Introduced on the S3048-ON.
9.7(0.0) Introduced on the S6000-ON.
9.2(1.0) Introduced on the Z9500.
9.0.2.0 Introduced on the S6000.
8.3.19.0 Introduced on the S4820T.
8.3.11.1 Introduced on the Z9000.
8.3.7.0 Introduced on the S4810.
8.2.1.0 Introduced on S-Series Stacking.
8.1.1.0 Introduced on the E-Series.
7.7.1.0 Introduced on the S-Series.
7.6.1.0 Introduced on the C-Series.
7.4.1.0 Introduced on the E-Series.
Usage
Information
This command sets the counter polling interval for an interface.
Related
Commands
sflow polling-interval (Global) globally sets the polling interval.
sflow sample-rate (Global)
Change the global default sampling rate.
Syntax
sflow sample-rate value
To return to the default sampling rate, use the no sflow sample-rate command.
Parameters
value
Enter the sampling rate value. For the C-Series and S-Series, the range is from
256 to 8388608 packets Enter values in powers of 2 only; for example, 4096, 8192,
16384, and so on. The default is 32768 packets.
Defaults 32768 packets
sFlow 1291