Users Guide

Table Of Contents
Version Description
9.8(2.0) Introduced on the S3100 series.
Usage
Information
The power inline mode command allows you to manage inline power supply on the stack unit. You
can configure class or static mode to manage inline power in a stack unit.
When class mode is configured, maximum power for the particular class of device is allocated. Class
mode supports power allocation via Layer 2 classification and power negotiation by Link Layer Discovery
Protocol (LLDP) 802.3at standard . When static mode is configured, the inline power is allocated based
on the actual power consumption by the powered device. Power negotiation via LLDP is not supported in
static mode.
Example
Example for static mode:
Dell(conf)#power inline mode stack-unit 1 static
Dell#show power inline stack-unit 1
Global inline power Threshold : 10
Power Reserved for inline Power: 95W
Total Inline Power Consumed: 0W
Remaining inline power Available: 95W
Power Management Mode: Static
Interface Inline Power Inline Power Class Device PoE Port
LLDP
Max / Alloc Consumed Type Priority
Support
(Watts) (Watts)
--------- ------------ ------------ ------- ------ --------
------
Gi 1/1 30.00/0.00 0.00 NO_DEVICE - high
Dell#
Example for class mode:
Dell(conf)#power inline mode stack-unit 1 class
Dell#show power inline stack-unit 1
Global inline power Threshold : 10
Power Reserved for inline Power: 95W
Total Inline Power Consumed: 0W
Remaining inline power Available: 95W
Power Management Mode: Class
Interface Inline Power Inline Power Class Device PoE Port
LLDP
Max / Alloc Consumed Type Priority
Support
(Watts) (Watts)
--------- ------------ ------------ ------- ------ --------
------
Gi 1/1 0.00 /0.00 0.00 NO_DEVICE - high
-
Dell#
power inline restore
You can use this command to enable the temporarily suspended PoE power supply to all the ports in a stack unit.
Syntax
power inline restore stack-unit unit number
1064 Power over Ethernet (PoE)