Users Guide
1 1 not present No Module 0
2 1 not present No Module 0
4 1 not present No Module 0
-- Power Supplies --
Unit Bay Status Type FanStatus FanSpeed(rpm)
---------------------------------------------------------------------------
1 1 down UNKNOWN down 0
1 2 up AC up 7728
2 1 absent absent 0
2 2 up AC up 8032
4 1 up AC up 7824
4 2 absent absent 0
-- Fan Status --
Unit Bay TrayStatus Fan0 Speed Fan1 Speed
------------------------------------------------------------------------------------
1 1 up up 7058 up 7058
2 1 up up 7164 up 7058
4 1 up up 7058 up 7058
Speed in RPM
Dell#
Stacking LAG
When multiple links are used between stack units, Dell Networking OS automatically bundles them in a stacking LAG to provide
aggregated throughput and redundancy.
The stacking LAG is established automatically and transparently by Dell Networking OS (without user configuration) after
peering is detected and behaves as follows:
• The stacking LAG dynamically aggregates; it can lose link members or gain new links.
• Shortest path selection inside the stack: If multiple paths exist between two units in the stack, the shortest path is used.
Stacking 776