Administrator Guide

Version Description
9.0.2.0 Introduced on the S6000.
8.3.19.0 Introduced on the S4820T.
8.3.11.1 Introduced on the Z9000.
8.3.7.0 Introduced on the S4810.
8.2.1.0 Introduced on the E-Series (IPv6).
8.1.1.0 Introduced on the E-Series (IPv4).
7.8.1.0 Increased the name string to accept up to 140 characters. Prior to 7.8.1.0, names
were up to 16 characters long.
7.6.1.0 Introduced on the S-Series.
7.5.1.0 Introduced on the C-Series.
7.4.1.0 Introduced on the E-Series.
Usage
Information
When you have exhausted all the sequence numbers, this feature permits re-assigning a new sequence
number to entries of an existing access-list.
seq
Assign a sequence number to a deny or permit filter in an IP access list while creating the filter.
Syntax
seq sequence-number {deny | permit} {source [mask] | any | host ip-
address}} [count [byte] | log] [dscp value] [ecn value] [fragments]
[monitor] [no-drop] [order]
To delete a filter, use the no seq sequence-number command.
Parameters
sequence-
number
Enter a number from 0 to 4294967290.
deny Enter the keyword deny to configure a filter to drop packets meeting this
condition.
permit Enter the keyword permit to configure a filter to forward packets meeting this
criteria.
source
Enter an IP address in dotted decimal format of the network from which the packet
was received.
mask
(OPTIONAL) Enter a network mask in /prefix format (/x) or A.B.C.D. The mask,
when specified in A.B.C.D format, may be either contiguous or non-contiguous.
any Enter the keyword any to specify that all routes are subject to the filter.
host
ip-address
Enter the keyword host then the IP address to specify a host IP address or
hostname.
count (OPTIONAL) Enter the keyword count to count packets the filter processes.
bytes (OPTIONAL) Enter the keyword bytes to count bytes the filter processes.
log (OPTIONAL) Enter the keyword log to enter ACL matches in the log.
dscp (OPTIONAL) Enter the keyword dcsp to match to the IP DCSCP values. The range
is from 0 to 63.
ecn (OPTIONAL) Enter the keyword ecn to match to the ECN values. The range is
from 0 to 3.
order (OPTIONAL) Enter the keyword order to specify the QoS order for the ACL
entry. The range is from 0 to 254 (where 0 is the highest priority and 254 is the
196 Access Control Lists (ACL)