Administrator Guide
Version Description
9.0.0.0 Introduced on the Z9000.
8.3.19.0 Introduced on the S4820T.
8.3.12.0 Introduced on the S4810.
8.3.11.1 Introduced on the Z9000.
7.8.1.0 The output of the show environment fan command for the S Series is
changed to display fan speeds instead of showing the fan status as up or down.
Usage
Information
The following example shows the output of the show environment command.
Example (all)
Example (System
Power Log)
DellEMC# show env
-- Fan Status --
Unit Bay TrayStatus Fan1 Speed Fan2 Speed
-------------------------------------------------------
1 1 up up 9056 up 9056
1 2 up up 9037 up 9037
Speed in RPM
-- Power Supplies --
Unit Bay Status Type FanStatus FanSpeed(rpm)
--------------------------------------------------------
1 1 up AC up NA
1 2 up AC up NA
Unit TotalPower AvgPower AvgPowerStartTime
------------------------------------------------
1 30 26 05/25/2017-19:18
show inventory
Display the switch type, components (including media), and Dell EMC Networking Operating System (OS), including hardware
identification numbers and configured protocols.
Syntax
show inventory [media slot]
Parameters
media
slot
(OPTIONAL) Enter the keyword media then the stack ID of the stack member for
which you want to display pluggable media inventory.
NOTE: This parameter is available but not supported in Dell EMC Networking
Operating System version 8.3.11.4. Because stacking is not supported, if you
use this parameter, the output displays “Media not present or accessible”
(refer to the Usage Information section).
Defaults none
Command Modes CONFIGURATION
Command
History
This guide is platform-specific. For command information about other platforms, see the relevant Dell
EMC Networking OS Command Line Reference Guide.
Version Description
9.11(0.0) Added support to display 10GBASE-T information on the S4048, S4048T, S6000,
S6000-ON, S6100, Z9500, S6010, and Z9100.
9.10(0.1) Introduced on the S6010-ON and S4048T-ON.
Control and Monitoring 129