Users Guide
Power Reserved for inline Power: 95W
Total Inline Power Consumed: 0W
Remaining inline power Available: 95W
Power Management Mode: Static
Interface Inline Power Inline Power Class Device PoE Port LLDP
Max / Alloc Consumed Type Priority Support
(Watts) (Watts)
--------- ------------ ------------ ------- ------ -------- ------
Gi 1/1 30.00/0.00 0.00 NO_DEVICE - high
Dell#
Example for class mode:
Dell(conf)#power inline mode stack-unit 1 class
Dell#show power inline stack-unit 1
Global inline power Threshold : 10
Power Reserved for inline Power: 95W
Total Inline Power Consumed: 0W
Remaining inline power Available: 95W
Power Management Mode: Class
Interface Inline Power Inline Power Class Device PoE Port LLDP
Max / Alloc Consumed Type Priority Support
(Watts) (Watts)
--------- ------------ ------------ ------- ------ -------- ------
Gi 1/1 0.00 /0.00 0.00 NO_DEVICE -
high -
Dell#
power inline restore
You can use this command to enable the temporarily suspended PoE power supply to all the ports in a stack unit.
Syntax
power inline restore stack-unit unit number
Parameters
stack-unit
unit
number
Enter the keyword stack-unit and the stack-unit number. Range is from 1 to 12.
Defaults None
Command Modes EXEC
Command History
This guide is platform-specific. For command information about other platforms, refer to the relevant Dell
Networking OS Command Line Reference Guide.
The following is a list of the Dell Networking OS version history for this command.
Version Description
9.10(0.0) Increased the stacking range to 12 units in S3100 series.
9.8(2.0) Introduced on the S3100 series.
Usage Information
The power inline restore command enables or restores the temporarily suspended PoE power supply to
all the ports on a stack unit.
Example
Dell#power inline restore stack-unit 1
Power over Ethernet (PoE) 1033