Users Guide
Parameters
stack-unit
unit
number
Enter the keyword stack-unit and the unit number. Range is 1 to 12.
Defaults Enabled
Command Modes CONFIGURATION
Command History
This guide is platform-specific. For command information about other platforms, refer to the relevant Dell
Networking OS Command Line Reference Guide.
The following is a list of the Dell Networking OS version history for this command.
Version Description
9.10(0.0) Increased the stacking range to 12 units in S3100 series.
9.8(2.0) Introduced on the S3100 series.
Usage Information
The power inline legacy command allows the system to detect and allocate inline power to the legacy
devices on a stack unit.
Example
Dell(conf)#power inline legacy stack-unit 1
power inline mode
Use this command to configure PoE power management mode for a specified stack member.
Syntax
power inline mode stack-unit unit number { class | static }
Parameters
stack-unit
unit
number
Enter the keyword stack-unit and the unit number. Range is 1 to 12.
class Enter the keyword class to configure the class mode for the specified stack unit.
static Enter the keyword static to configure the static mode for the specified stack unit.
Defaults Static
Command Modes CONFIGURATION
Command History
This guide is platform-specific. For command information about other platforms, refer to the relevant Dell
Networking OS Command Line Reference Guide.
The following is a list of the Dell Networking OS version history for this command.
Version Description
9.10(0.0) Increased the stacking range to 12 units in S3100 series.
9.8(2.0) Introduced on the S3100 series.
Usage Information
The power inline mode command allows you to manage inline power supply on the stack unit. You can
configure class or static mode to manage inline power in a stack unit.
When class mode is configured, maximum power for the particular class of device is allocated. Class mode
supports power allocation via Layer 2 classification and power negotiation by Link Layer Discovery Protocol
(LLDP) 802.3at standard . When static mode is configured, the inline power is allocated based on the actual
power consumption by the powered device. Power negotiation via LLDP is not supported in static mode.
Example
Example for static mode:
Dell(conf)#power inline mode stack-unit 1 static
Dell#show power inline stack-unit 1
Global inline power Threshold : 10
1032 Power over Ethernet (PoE)