Administrator Guide

show hardware stack-unit {1–12} cpu management statistics
View driver-level statistics for the data-plane port on the CPU for the specified stack-unit.
EXEC Privilege mode
show hardware stack-unit {1–12} cpu data-plane statistics
This view provides insight into the packet types entering the CPU to see whether CPU-bound traffic is internal (IPC traffic) or
network control traffic, which the CPU must process.
View input and output statistics on the party bus, which carries inter-process communication traffic between CPUs.
EXEC Privilege mode
show hardware stack-unit {1–12} cpu party-bus statistics
View the ingress and egress internal packet-drop counters, MAC counters drop, and FP packet drops for the stack unit on per port
basis.
EXEC Privilege mode
show hardware stack-unit {1–12} drops unit {0-0}
This view helps identifying the stack unit/port pipe/port that may experience internal drops.
View the input and output statistics for a stack-port interface.
EXEC Privilege mode
show hardware stack-unit {1–12} stack-port {portnumber}
View the counters in the field processors of the stack unit.
EXEC Privilege mode
show hardware stack-unit {1–12} unit {0-0} counters
View the details of the FP Devices and Hi gig ports on the stack-unit.
EXEC Privilege mode
show hardware stack-unit {1–12} unit {0-0} details
View the Multicast IPMC replication table from the bShell.
EXEC Privilege mode
show hardware stack-unit {1–12} unit {0-0} ipmc-replication
View the internal statistics for each port-pipe (unit) on per port basis.
EXEC Privilege mode
show hardware stack-unit {1–12} unit {0-0} port-stats [detail]
View the stack-unit internal registers for each port-pipe.
EXEC Privilege mode
show hardware stack-unit {1–12} unit {0-0} register
View the tables from the bShell through the CLI without going into the bShell.
EXEC Privilege mode
show hardware stack-unit {1–12} unit {0-0} table-dump {table name}
Enabling Environmental Monitoring
The device components use environmental monitoring hardware to detect transmit power readings, receive power readings, and
temperature updates.
To receive periodic power updates, you must enable the following command.
Enable environmental monitoring.
enable optic-info-update interval
DellEMC#show interfaces tengigabitethernet 1/25 transceiver
Interface Name : TenGigabitEthernet 1/25
SFP is present
SFP+ 1638400 Serial Base ID fields
SFP+ 1638400 Id = 0x03
SFP+ 1638400 Ext Id = 0x04
SFP+ 1638400 Connector = 0x21
SFP+ 1638400 Transceiver Code = 0x01 0x00 0x00 0x00 0x41 0x84 0x80 0x55
SFP+ 1638400 Encoding = 0x00
SFP+ 1638400 BR Nominal = 0x67
SFP+ 1638400 Length(SFM) Km = 0x00
SFP+ 1638400 Length(OM3) 2m = 0x00
Debugging and Diagnostics
983