Administrator Guide

Unit UnitType Status ReqTyp CurTyp Version Ports
------------------------------------------------------------------------------------
1 Member not present
2 Management online S3148P S3148P 1-0(0-4679) 54
3 Standby online S3148P S3148P 1-0(0-4679) 54
4 Member not present
5 Member not present
6 Member not present
7 Member not present
8 Member not present
9 Member not present
10 Member not present
11 Member not present
12 Member not present
-- Module Info --
Unit Module No Status Module Type Ports
---------------------------------------------------------------------------
2 1 online S3148P-10GE-2SFP+ 2
3 1 online S3148P-10GE-2X10BaseT 2
-- Power Supplies --
Unit Bay Status Type FanStatus FanSpeed(rpm)
---------------------------------------------------------------------------
2 1 up AC up NA
2 2 absent absent NA
3 1 absent absent 0
3 2 up AC up 7888
-- Fan Status --
Unit Bay TrayStatus Fan1 Speed Fan2 Speed
------------------------------------------------------------------------------------
2 1 up up 6956 up 7058
3 1 up up 7058 up 7164
Speed in RPM
DellEMC#
NOTE:
Each unit in the stack has a stack number that is either assigned by you or Dell EMC Networking OS. To manually
renumber stack members, use the stack-unit old-unit-number renumber new-unit-number command.
Renumbering stack members causes the entire stack to reload.
Troubleshoot a Stack
To troubleshoot a stack, use the following recovery tasks.
Recover from Stack Link Flaps
Recover from a Card Problem State on a Stack
Recover from Stack Link Flaps
Stack link integrity monitoring enables units to monitor their own stack ports and disable any stack port that flaps five times within 10
seconds.
Dell EMC Networking OS displays console messages for the local and remote members of a flapping link, and on the primary (master) and
standby management units as KERN-2-INT messages if the flapping port belongs to either of these units.
In the following example, a stack-port on the master flaps. The remote member, Member 2, displays a console message, and the master
and standby display KERN-2-INT messages.
To re-enable the downed stack-port, power cycle the offending unit.
Example of Console Messages About Flapping Link
DellEMC#00:42:46: %S3148P:2 %IFAGT-5-STACK_PORT_LINK_DOWN: Changed stack port state to down:
2/54
00:42:48: %S3148P:4 %IFAGT-5-STACK_PORT_LINK_UP: Changed stack port state to up: 4/53
00:42:48: %S3148P:2 %IFAGT-5-STACK_PORT_LINK_UP: Changed stack port state to up: 2/54
816
Stacking