Deployment Guide

96
set logging component command
Use this API to set the runtime logging components on the switch until rebooted. Use the “set default
logging …” command to store the setting into the system flash running-configuration
Example
FJ6K0Z1_console> set logging
set logging <subcommand>
possible subcommands:
component set component for logging
level
FJ6K0Z1_console> set logging component
set logging component command: valid components are 0-5
FJ6K0Z1_console> help set logging component
set logging component <component>
Set component for logging where component is:
0 = NONE
1 = API
2 = MAPPING
3 = OFDB
4 = DATAPATH
5 = ALL
set logging level command
Use this API to set the runtime logging level for the switch until rebooted. Use the “set default logging …”
command to store the setting into the system flash running-configuration
Example
FJ6K0Z1_console> set logging level
set logging level <level>
Set the logging level. Values above 3 should probably not be turned on for
serial port backed IO like screen consoles/maintenance ports.
The level can be:
0 = OFF (FATAL only)
1 = BASIC (FATAL,ERROR,WARNING)
2 = INFO (FATAL,ERROR,WARNING,INFO)
3 = MESSAGE (FATAL,ERROR,WARNING,INFO,MESSAGEs)
4 = VERBOSE (and then some)
5 = TRACING
6 = ALMOST ALL (except for in progress debugging)
7 = ALL
set dscp-trust command
This command enables the DSCP to egress queue mapping for a packet.
Example
FJ6K0Z1_console> set dscp-trust <port>
Set dscp-trust for a port
FJ6K0Z1_console> set dscp-trust 2