4.4.2.1 Naming Convention
Table 46 details the DNOS-OF L2 Interface group entry identifier subfields that encode combinations of egress
port and VLAN ID.
4.4.2.2 Action Buckets
The single action bucket specifies the output port, and whether or not the packet is egressed tagged.
Although the pop action is a NOP if the packet has no VLAN tag, packets should always have a VLAN tag
when the actions in the output group table are applied.
Note: If the packet came in untagged and a port VLAN was assigned, a VLAN tag was pushed as a VLAN Flow
Table action.
Table 47: DNOS-OF L2 Interface Group Entry Bucket Actions
Field
Argument
Description
Output
Port
Physical output port.
Pop VLAN
None
Pop the VLAN tag before sending the packet.
Set Field
DSCP
Static DSCP value for IP packets
Set Field
VLAN PCP
Static 802.1p value
Set-Field
VLAN DEI
Static 802.1p value
Clearly DNOS-OF L2 Interface group entries must be defined before being used. DNOS-OF maintains
reference counts for used entries, and an entry cannot be deleted if it is referenced by a flow entry or another
group.
4.4.2.3 Counters