Deployment Guide
106
set power management dynamic command
Use the set power management dynamic command to set the PoE power management mode to dynamic
mode.
Example
FJ6K0Z1_console> set power management dynamic
PoE power management mode set to dynamic
set power management static command
Use the set power management static command to set the PoE power management mode to static
mode.
Example
FJ6K0Z1_console> set power management static
PoE power management mode set to static
set power priority command
Use the set power priority command to set the PoE power priority on a given port to the indicated value.
Example
FJ6K0Z1_console> set power priority <priority> <port>
FJ6K0Z1_console> set power priority low 1
PoE power inline priority set to low
set power priority critical command
Use the set power priority critical command to set the PoE power priority on a given port to critical.
Example
FJ6K0Z1_console> set power priority critical <port>
FJ6K0Z1_console> set power priority critical 3
PoE power inline priority set to critical
set power priority high command
Use the set power priority high command to set the PoE power priority on a given port to high.
Example
FJ6K0Z1_console> set power priority high <port>
FJ6K0Z1_console> set power priority high 3
PoE power inline priority set to high
set power priority low command
Use the set power priority low command to set the PoE power priority on a given port to low.
Example
FJ6K0Z1_console> set power priority low <port>
FJ6K0Z1_console> set power priority low 3
PoE power inline priority set to low