Quick Reference Guide
Green Ethernet Commands 435
Syntax
green-mode eee-lpi-history {sampling-interval
30 sec
–
36000 sec
| max-
samples
1
-
168
}
•
sampling-interval
—The interval in seconds at which power consumption
data needs to be collected.
•
max-samples
—Maximum number of samples to keep.
Default Configuration
The sampling-interval default value is 3600 seconds and the max-samples
default value is 168.
Command Mode
Global Configuration
User Guidelines
EEE and energy-detect modes are only supported on N4000 series 10G
copper ports and on N2000/N3000 1G and 10G copper ports.
Examples
Use the command below to set the EEE LPI History sampling interval to the
default.
console(config)# no green-mode eee-lpi-history sampling-interval
Use the command below to set the EEE LPI History max-samples to the
default.
console(config)#no green-mode eee-lpi-history max-samples
show green-mode
interface-id
Use the show green-mode
interface-id
command in Privileged EXEC mode
to display the green-mode configuration and operational status of the port.
This command is also used to display the per port configuration and
operational status of the green-mode. The status is shown only for the modes
supported on the corresponding hardware platform whether enabled or
disabled.