Service Manual

24 Installation Guide
Verifying Installation
In order to ensure the InfiniBand network is setup correctly and to check the
connectivity across the cluster, run the HPC Cluster Manager's built-in
Message Passing Interface (MPI) Ping-Pong utility. This test validates the
driver stack, the network protocol, MPI implementation and helps identify
any anomalies in the node-to-node connection.
Under the Diagnostics pane in the HPC Cluster Manager, click
Tests System Performance MPI-Ping-Pong.
NOTE: You can select either or both Lightweight Throughput or Quick Check tests.
Lightweight Throughput test reports the average of the total bandwidth of
the cluster and helps identify slow and fast links across nodes. The Quick
Check test reports the overall latency across the cluster.
Deploying iSCSI Boot Nodes
iSCSI boot nodes is one of the supported features with Windows HPC Server
2008 R2. This section describes the process of deploying iSCSI boot nodes on
Windows HPC clusters.
Broadcom iSCSI and System BIOS Settings on iSCSI Boot Nodes
For Broadcom iSCSI settings:
1
Press <CTRL><S> or <CTRL><K> to access the Broadcom iSCSI
BIOS settings.
2
Set the TCP and iSCSI parameters via DHCP enabled.
3
Set boot to iSCSI target as enabled.
4
Set target first HDD as enabled.
For system BIOS settings:
1
Press <F2>.
2
Disable integrated SAS controller.
3
Enable NIC1 with iSCSI boot.
book.book Page 24 Monday, September 20, 2010 1:36 PM