Service Manual

18 Installation Guide
Bxvbd.inf
under the location
C:\Broadcom\Program Files 64\
Broadcom\BDrv5706\VBD
Bxnd.inf
under the location
C:\Broadcom\Program Files 64\
Broadcom\BDrv5706\Win2k8
B57amd64.inf
under the location
C:\Broadcom\Program Files 64\
Broadcom\BDRVINST
B57nd60a.inf
and
b57ports.inf
under the location
C:\Broadcom\Program Files 64\ Broadcom\BDRVINST
7
If a storage driver (PERC S100 or S300) is required for the compute nodes,
extract the contents of the driver package to the default location. For
example:
C:\dell\drivers\..
.
Use the
Add
button in the
Manage Drivers
window to add the required
storage drivers.
8
Click
Close
in the
Manage Drivers
window.
After the HPC configuration is complete, follow the steps in "Installing the
Compute Nodes" on page 18.
Installing the Compute Nodes
1
On the head node, open
HPC Cluster Manager
. Click
Options

Deployment Settings
and select
Respond to all PXE requests
. This
enables the head node to initiate the installation of the compute nodes
through the network.
2
Ensure that the compute nodes are on the same network as the private
interface of the head node. Boot the compute nodes through PXE. If this is
not the default boot option for the compute nodes, assign PXE as the first
boot option in the system BIOS.
3
On the head node, open the
Node Management
pane. The nodes that
boot over PXE appear in the
Nodes list
. Select the nodes on the list, right-
click and select
Assign Node Template...
4
In the
Assign Node Template
window, select
Dell SLP ComputeNode
Template
and click
OK
.
After assigning the template, the compute nodes are installed
and configured.
book.book Page 18 Monday, September 20, 2010 1:36 PM