Reference Guide

Condition
ID
Severity Call home Alert name Descriptio
n
RCA Corrective
action
Event
source
Alert type
replace the
SFP.
0xa0002 Critical True SFP Rx
Power Low
A port RX
power is
below the
warning or
alarm
threshold.
A port's RX
power is
below the
warning or
alarm
threshold.
The
hardware
attached to
this port
must be
carefully
investigated
, and the
switch port
SFP and
cable should
be re-
seated,
cleaned, and
swapped as
needed.
INTERFACE Alarm
0xa0003 Critical True SFP Rx
Power High
A port RX
power is
above the
warning or
alarm
threshold.
A port's RX
power is
above the
warning or
alarm
threshold.
The
hardware
attached to
this port
must be
carefully
investigated
, and the
switch port
SFP and
cable should
be re-
seated,
cleaned, and
swapped as
needed.
INTERFACE Alarm
0xa0004 Critical True SFP Tx
Power Low
A port TX
power is
below the
warning or
alarm
threshold.
A port's TX
power is
below the
warning or
alarm
threshold.
Contact Dell
EMC
Customer
Support to
replace the
SFP.
INTERFACE Alarm
0xa0005 Critical True SFP Tx
Power High
A port TX
power is
above the
warning or
alarm
threshold.
A port's TX
power is
above the
warning or
alarm
threshold.
Contact Dell
EMC
Customer
Support to
replace the
SFP.
INTERFACE Alarm
0x13006f ERROR True Discoverer
Header CRC
Error
The local
port
received an
invalid
header from
the remote
port (CRC
check
failed).
A tcpcom
connection
header
failed to
pass CRC
checks.
The system
should
recover
automaticall
y. However,
the
underlying
network and
hardware
must be
investigated
to
PORT Operational
Events and Alerts 53