Reference Guide

Condition
ID
Severity Call home Alert name Descriptio
n
RCA Corrective
action
Event
source
Alert type
not written
to the non-
volatile file
system
occurred
and data
was not
written to
the non-
volatile file
system
occurred to
the non-
volatile file
system and
data was
not written
to disk.
to the
meta-
volume
failed. If the
failure
cannot be
corrected,
create a
new meta-
volume and
copy the in-
memory
data to the
new meta-
volume.
Contact Dell
Customer
Support for
assistance if
necessary.
0x40001 WARNING True Director
running a
different
version of
the
software
detected.
Director
running a
different
version of
the
software
detected.
Local
directors
are running
different
versions of
software.
Contact Dell
Customer
Support.
DIRECTOR Operational
0x40002 WARNING True The number
of COM
paths to
remote
director is
smaller than
expected in
a standard
configuratio
n.
The number
of COM
paths to
remote
director is
smaller than
expected in
a standard
configuratio
n.
Fewer than
expected
paths to
remote
director.
Check the
state of the
COM port,
making sure
it is enabled.
Check the
cable,
making sure
it is properly
plugged in.
Check the
switch if
applicable,
making sure
it is
operational
and the
correspondi
ng port is
enabled.
Contact Dell
Customer
Support if
this event
persists.
DIRECTOR
Operational
0x40003 ERROR True The system
failed to
read an
internal
setting.
The system
failed to
read an
internal
setting.
The system
failed to
read an
internal
setting. It
will prevent
the director
from fully
Contact Dell
Customer
Support.
DIRECTOR Operational
44 Events and Alerts