Reference Guide
Table Of Contents
- Dell EMC Storage Systems Events and Alerts Guide for the metro node appliance
- Contents
- Events and Alerts
- UI overview
- Platform alerts
- Hardware alerts
- Alert states
- Scope of the events
- Sorting and filtering alerts
- Download .csv
- Default and hidden columns
- Live alerts
- Alerts roll-up
- Historical alerts
- Alerts on remote director
- Configure alerts
- Service Monitoring Alert
- Test alerts for platform, monitor, and SMS
- Heartbeat alerts
- Mail notification
- Configure emailing notification
- Test email alert
- Supported events
Condition
ID
Severity Call home Alert name Descriptio
n
RCA Corrective
action
Event
source
Alert type
the cluster.
Also a
communicat
ions link
could have
been
brought up
by mistake,
allowing a
cluster of a
different
version to
be visible.
firmware
was
inserted into
the cluster
and booted,
then shut
down that
director. If
the situation
arose
because a
communicat
ions link has
been
brought up
by mistake,
then take
down that
communicat
ions link.
0x60005 WARNING True Witness
Com Node
From
Foreign Site
Unexpected
membership
arrival uuid
{directorId}
appears
from foreign
cluster
{foreignClus
terId}.
A director
from a
foreign
metro node
cluster was
unexpectedl
y discovered
through this
cluster.
Contact Dell
Customer
Support to
check if
there has
been a mis-
configuratio
n done
between
clusters in
the
environment
.
CLUSTER Operational
0x90001 ERROR True SCSI Target
Reset
received for
host IT
Nexus
SCSI Target
Reset
received for
host IT
Nexus.
Host
initiator has
issued
target reset
due to slow
I/O
processing.
Check I/O
processing
statistics.
Identify the
reason for
the host to
issue Target
Reset and
resolve it. If
the problem
is with the
host,
unzone the
initiator in
question
from the
fabric to
prevent
potential
performanc
e impact to
other hosts
until the
issue can be
resolved.
Contact Dell
Customer
TARGETPO
RT
Operational
Events and Alerts 37