Reference Guide

Condition
ID
Severity Call home Alert name Descriptio
n
RCA Corrective
action
Event
source
Alert type
metadata to
a metadata
volume.
has been
written out
to the given
metadata
volume.
No action is
required.
0x3001e CRITICAL False Metadata
Copy Failed
Failed to
copy in-
memory
metadata to
a metadata
volume.
An attempt
to write out
all in-
memory
metadata to
a metadata
volume
failed.
Examine the
metadata
volume to
see if there
are any
problems
that can be
corrected,
contacting
Dell
Customer
Service for
assistance if
needed.
METAVOLU
ME
Operational
0x3001f INFO False Metadata
Move
Succeeded
Successfully
copied in-
memory
metadata to
a metadata
volume,
which is
now the
active
metadata
volume.
All in-
memory
metadata
has been
written out
to the given
metadata
volume,
which is
now the
active
metadata
volume.
It is an
informationa
l event only.
No action is
required.
METAVOLU
ME
Operational
0x30020 CRITICAL False Metadata
Move Failed
Failed to
copy in-
memory
metadata to
a metadata
volume, and
therefore
the
metadata
volume has
not been
activated.
An attempt
to write out
all in-
memory
metadata to
a metadata
volume
failed, and
therefore
that
metadata
volume has
not been
activated.
Examine the
metadata
volume to
see if there
are any
problems
that can be
corrected,
contacting
Dell
Customer
Service for
assistance if
needed.
METAVOLU
ME
Operational
0x60001 ERROR True Cluster
Partition
Cluster has
partitioned.
The last
director
with the
given
cluster id
has
departed. It
marks the
loss of the
indicated
cluster from
the point of
viewof the
The last
director
with the
given
cluster ID
has
departed. It
marks the
loss of the
indicated
cluster from
the point of
view of the
CLUSTER Alarm
Events and Alerts 35