Reference Guide
Table Of Contents
- Dell EMC Storage Systems Events and Alerts Guide for the metro node appliance
- Contents
- Events and Alerts
- UI overview
- Platform alerts
- Hardware alerts
- Alert states
- Scope of the events
- Sorting and filtering alerts
- Download .csv
- Default and hidden columns
- Live alerts
- Alerts roll-up
- Historical alerts
- Alerts on remote director
- Configure alerts
- Service Monitoring Alert
- Test alerts for platform, monitor, and SMS
- Heartbeat alerts
- Mail notification
- Configure emailing notification
- Test email alert
- Supported events
Condition
ID
Severity Call home Alert name Descriptio
n
RCA Corrective
action
Event
source
Alert type
Support to
restore from
the backup.
0x3001a WARNING True Storage
Volume
Latency
Degraded
Storage
volume I/O
latency has
increased
above an
acceptable
threshold.
The average
I/O latency
on a storage
volume has
exceeded
the
acceptable
limit, likely
due to
increased
latency on
the backend
storage
array or
fabrics
between the
metro node
and storage
array.
1. Analyze
the latency
stats from
the storage
array for the
volume in
question at
the time of
the event to
determine if
it reported
the same
high
latency.
Engage the
storage
array vendor
as needed.
2. If the
storage
array does
not report
the same
latency at
the time of
the issue for
the volume,
then
investigate
the fabrics
between the
metro node
and storage
array. 3. If
the issue
persists and
the cause
cannot be
determined
engage Dell
Customer
Service.
STORAGEV
OLUME
Alarm
0x3001b WARNING True Remote
Device
Latency
Degraded
Remote
device I/O
latency has
increased
above an
acceptable
threshold.
The average
I/O latency
on a remote
device has
exceeded
the
acceptable
limit due to
possible
issues on
the back-
end or WAN
link.
1. Use the
metro node
Unisphere
performanc
e monitoring
stats to
verify if
there is high
average I/O
latency on
the WAN
COM links,
or high
average
backend I/O
DISTRIBUTE
DDEVICE
Alarm
32 Events and Alerts










