Reference Guide

Condition
ID
Severity Call home Alert name Descriptio
n
RCA Corrective
action
Event
source
Alert type
investigate
the cause of
the
performanc
e
degradation.
3. Compare
the storage-
volume
latency
stats to the
latency on
the storage
array for the
one or more
volumes in
question. If
the latency
on the array
is not as
high
investigate
the fabrics
between the
storage
array and
metro node.
4. If the
issue
persists and
unable to
determine
the cause
engage Dell
Customer
Service.
0x30014
CRITICAL True Device
Detach Full
Rebuild
A complex
sequence of
failures has
led to
marking one
mirror of a
distributed
device fully
out of date,
and to the
temporary
suspension
of I/O on
that
distributed
device.
A
combination
of failures
involving
metadata
and disks
offline at
cluster
followed by
cluster
partition and
failed writes
to a logging
volume has
led to
temporary
condition
where the
distributed
device can
no longer
process I/O.
Once this
condition is
resolved, a
A full rebuild
is started
automaticall
y once the
clusters
rejoin.
Investigate
why the
clusters are
partitioned
and take
any required
actions to
restore the
WAN COM
connectivity
so the
clusters can
rejoin.
DISTRIBUTE
DDEVICE
Operational
Events and Alerts 29