Reference Guide

Condition
ID
Severity Call home Alert name Descriptio
n
RCA Corrective
action
Event
source
Alert type
maintaining
a list of
changes to
the reported
distributed
device. The
specified
mirror of
the
distributed
device is
marked out
of date and
rebuilt when
possible.
the
accessibility
of the
underlying
storage-
volume of
the mirror
that is
marked out
of date. If
necessary,
to
reconnect
the
inaccessible
storage-
volumes,
take
corrective
actions.
Contact Dell
Customer
Support for
assistance.
0x3000a CRITICAL True All Mirrors
Out of Date
All mirrors
of the
distributed
device are
out of date,
choosing
one mirror
as up to
date to
allow access
to the
device.
All the
mirrors of
the
specified
distributed
device had
been
marked out
of date. In
order to
restore
access to
the device,
and to
minimize
data loss,
the
specified
mirror was
marked as
up to date.
Contact Dell
Customer
Support.
VIRTUALVO
LUME
Operational
0x3000b ERROR True Device
Name
Conflict
Name
conflict
detected
between
two devices,
renaming
the second
occurrence.
Two
discovered
devices
reported the
same device
name. It can
occur if
configuratio
n changes
are made
when one or
more
storage
volumes are
unreachable
Manual
intervention
is required.
Contact Dell
Customer
Support to
resolve the
conflict.
DEVICE Operational