Reference Guide

Condition
ID
Severity Call home Alert name Descriptio
n
RCA Corrective
action
Event
source
Alert type
identifiers. If
either of
these
conditions
occur, do
not use this
array. The
array name
and version
number
should be
reported to
Dell
Customer
support.
Continuing
to use the
array could
lead to Data
Unavailabilit
y and Data
Loss
conditions
and
unreliable
array
behavior.
0x2000b
ERROR True Logical Unit
Changed
Logical Unit
mappings
change
detected.
For this ITL,
a different
Logical Unit
is reported
than what
was
reported
earlier.
LU mapping
on the
storage
array had
changed.
Depending
on the state
of the
system
(host IOs
running or
not), either
Data
Unavailable,
Data Loss or
Data
Corruption
might have
already
happened or
might
happen in
future.
The system
automaticall
y runs a
refresh to
destroy the
stale ITL to
the old LUID
and re-
discover the
ITL to the
new LUID.
Always
follow the
'Remove
Disk or
Array'
procedure in
the metro
node SolVe
Desktop
when de-
provisioning
storage-
volumes
and/or re-
provisioning
storage-
volumes to
metro node
to ensure an
'array re-
discover' is
run in
between
ITLNEXUS
Alarm