Owner's Manual

Microsoft System Center Essentials (SCE) 2010
Issue 3:
When EMM firmware does not match the MD Storage Array, OpsMgr may show the EMM as healthy - (473374).
Workaround:
You need to check for EMM Firmware mismatch alerts in MD Storage Array Alerts view and take appropriate
action as specified in the Alert's Knowledge Article.
Versions Affected
:
Microsoft System Center 2012 SP1 Operations Manager
Microsoft System Center 2012 Operations Manager
Microsoft System Center Operations Manager (SCOM) 2007 R2
Microsoft System Center Essentials (SCE) 2010
Issue 4:
Fan position for daisy chained enclosure (MD1000) maybe shown incorrectly when daisy chained to MD3000 -
(492918).
Workaround:
You need to launch the Dell PowerVault Modular Disk Storage Manager (MDSM) to find the actual position of
the fan for MD1000.
Versions Affected
:
Microsoft System Center 2012 SP1 Operations Manager
Microsoft System Center 2012 Operations Manager
Microsoft System Center Operations Manager (SCOM) 2007 R2
Microsoft System Center Essentials (SCE) 2010
Platforms Affected:
MD1000 when daisy chained to MD3000/MD3000i
Issue 5:
Uninstallation of MD Storage Array management pack fails due to Operations Manager database transaction log
getting full - (469943).
Description:
When there is large amount of data related to the MD Storage Arrays in the Operations Manager database,
uninstall operation will cause Operations Manager database to delete the data causing the Operations Manager Database
transaction log to fill. When the transaction log is full and data deletion is not complete, the uninstall operationwill fail and
report a Database exception to the user with the message -- The transaction log for database 'Operations Manager' is full.
Workaround:
You need to increase Operations Manager transaction log size (5GB or as desired) temporarily and delete the
management pack. You can restore the transaction log size back to original settings after the management pack is deleted.
Versions Affected
:
Microsoft System Center 2012 SP1 Operations Manager
Microsoft System Center 2012 Operations Manager
Microsoft System Center Operations Manager (SCOM) 2007 R2
Microsoft System Center Essentials (SCE) 2010
Issue 6:
Deleting management pack from OpsMgr console, does not delete the MD Storage Array Alerts view and Diagram
view. If user clicks any of these views, an error is shown as "Object not found" - (310069).
Description:
After removing the imported management pack, the diagram view and alerts view should get cleaned up. If
the Base Management Pack is deleted or if user closes and re-opens the OpsMgr console then cleanup happens.
Workaround:
You need to restart OpsMgr Console with /clearcache option.
Versions Affected
:
Microsoft System Center 2012 SP1 Operations Manager
Microsoft System Center 2012 Operations Manager
Microsoft System Center Operations Manager (SCOM) 2007 R2