Owner's Manual
NOTE: You can specify the override parameters in the Authoring pane of the OpsMgr console.
Object Discoveries
To specify override parameters for object discoveries:
1. In the OpsMgr console, click Authoring.
2. In the Authoring pane, select Management Pack Objects → Object Discoveries.
3. Select MD Storage Array Seed Discovery → Dell MD Storage Array Seed Discovery.
NOTE: You may need to change the scope to locate the discovery.
4. Right-click the object discovery you want to override and select Overrides → Override the Object Discovery.
5. Check the appropriate discovery parameter that you want to override and set its Override Value.
6. Save the Override settings in a new management pack.
7. Click Apply.
8. Similarly select Dell MD Storage Array Discovery under the MD Storage Array Seed Discovery group object and
repeat step 4 to step 7 to override its discovery interval.
Unit Monitors
The following table provides information for the various unit monitors and the applicable parameters for the Dell
PowerVault MD Storage Arrays.
Component Unit Monitor Name Description Time Interval
MD Storage Array State
Information
Dell MD Array Device
Status (Periodic)
Unit Monitor for all MD
Storage Arrays: Tracks the
global health status of the
storage array.
4300 seconds (72 minutes)
Dell MD Array Battery Dell MD Array Device
Status (Periodic)
Unit Monitor for MD
Storage Array Batteries:
Indicates the health of the
storage array battery unit.
3600 seconds (60 minutes)
Dell MD Array Chassis Unmonitored None. None
Dell MD Array Fan Dell MD Array Fans Status
(Periodic)
Unit Monitor for MD
Storage Array Fans:
Indicates the health of the
storage array fan.
3600 seconds (60 minutes)
Dell MD Array Network
Interface
Unmonitored None. None
Dell MD Array Physical Disk Dell MD Array Physical
Disk Status (Periodic)
Unit Monitor for MD
Storage Array Physical
Disks: Indicates the health
of the storage array
physical disks.
3600 seconds (60 minutes)
15