Owner's Manual

14 | P a g e
Version Affected: 1.5, 1.5.1
Issue 13: A non-compliant server shows a CSIOR status as Unknown.
Resolution: An unknown CSIOR state indicates a non-responsive iDRAC on the
host. A manual iDRAC reset on the host fixes this problem.
Version Affected: 1.5, 1.5.1
Issue 14: The Launch OMSA link does not work in the vSphere Client Dell Tab
when using Dell PowerEdge 12th generation servers.
Resolution: Install OMSA manually onto Dell PowerEdge 12th generation
servers, then the Launch OMSA link will work.
Version Affected: 1.5, 1.5.1
Issue 15: Hardware Profile for iDRAC/network settings has incorrect modifiable
parameters.
Description: You can over write inside the combo boxes and save options that
are not supposed to be editable.
Resolution: None.
Version Affected: 1.5, 1.5.1
Issue 16: Hypervisor installation fails.
Description: Hypervisor installation fails with the error The Job check status
with ID of DCIM_OSConcreteJob:1 failed with the following error
message: Mount network share failed incorrect IP address or share name.
Resolution: Restart the appliance.
Version Affected: 1.5, 1.5.1