User's Manual
NOTE: Passwords can contain up to 20 printable ASCII characters. The domain name can contain
alphanumeric characters, - (dash), and . (period) only.
b) For Certificate Check, select Enable to download and store the iDRAC certificate and validate it during all future
connections, or select Disable to perform no check and not store the certificate.
You need to select Enable if you are using Active Directory.
6. Click Next.
7. In the Host Root Credentials panel, do the following:
a) Enter the User Name, Password, and Verify Password. The passwords must match.
NOTE: Passwords cannot exceed 31 characters and cannot contain any special characters.
NOTE: For servers that do not have either an iDRAC Express or Enterprise card, the iDRAC test connection
result states
Not Applicable for this system
.
NOTE: The OMSA credentials are the same credentials used for ESX and ESXi hosts.
b) For Certificate Check, select Enable to download and store the OMSA certificate and validate it during all future
connections, or select Disable to perform no check and not store the certificate. Select Enable if you use Active
Directory.
8. Click Next.
9. The Test Connection window tests the entered iDRAC and Host Root Credentials on the selected servers. Do one of
the following:
– To begin the test, click Test Selected The other options are inactive.
– To stop the tests click Abort All Tests.
10. To complete the profile, click Save.
11. To continue on to configure Events and Alarms, click Save and Continue.
Configuring Events And Alarms [Wizard]
Configure events and alarms using the Configuration Wizard or from the Dell Management Center, Settings option for
Events and Alarms.
NOTE: On hosts prior to 12G, this feature requires that the virtual appliance is configured as a trap destination in
OMSA to display host events in vCenter.
To configure events and alarms:
1. In the Configuration Wizard, under Event Posting Levels, select one of the following:
– Do not post any events - Block hardware events.
– Post All Events - Post all hardware events.
– Post only Critical and Warning Events - Post only critical or warning level hardware events.
– Post only Virtualization-Related Critical and Warning Events - Post only virtualization-related critical and
warning events; this is the default event posting level.
2. To enable all hardware alarms and events, select the Enable Alarms for Dell Hosts check box.
NOTE: Dell hosts that have alarms enabled respond to critical events by entering maintenance mode.
3. In the dialog box that displays, click Continue to accept this change, or click Cancel.
NOTE: This step is only seen if Enable Alarms For Dell Hosts is selected.
4. To restore the default vCenter alarm settings for all managed Dell servers, click Restore Default Alarms.
It may take up to a minute before the change takes effect.
5. To continue the wizard, click Save and Continue.
19