User's Manual

18 Introduction
3
Ty p e
Tas k n am e
,
Description
, and select
BMC for Dell Server
as the
Tas k Tar get
and
click
Next.
The
Command Line
screen appears
.
4
Type the path of the application
ipmish.exe
(the path where BMU was
installed on the Operator Console) in the
Application
field. For example,
C:\Program Files\Dell\SysMgt\bmc\ipmish.exe
5
In the
Parameters
field, enter the command line parameters in the
following format:
Type
-ip
and choose the
BMC IP Address
from the drop-down menu.
•Type
-u <BMC user name> -p <BMC password> -k <BMC
KG key> <IPMI Task String>
Replace
<IPMI Task String>
with one of the following options:
power status
(for
Check Power Status
task)
power on
(for
Power On
task)
power off
(for
Power Off
Gracefully
task)
power off -force
(for
Forced Power Off
task)
power cycle
(for
Power Cycle
task)
power reset
(for
Power Reset
task)
identify on
(for
LED Identification On
task)
identify off
(for
LED Identification Off
task)
A sample command line parameter entry:
-ip $Target/Property[Type=
"Dell.Connections00130025!Dell.Connections.
ServerBMC"]/BMCIPAddress$ -u root -p calvin
-k 0000 power status
6
Click
Create
to create the task and repeat this procedure for each new
BMC task you want to create.
book.book Page 18 Wednesday, August 6, 2008 9:44 AM