These are the known issues in SCOM 2007 SP1/SCE SP1:
1
The Dellâ„¢ Management Pack Diagram Views displays a blank screen
intermittently.
The Diagram View in SCOM 2007 SP1 displays a blank screen
intermittently. The actual diagram view will not come up even after
refreshing the screen several times.
2
Dell Servers disappear from the SCOM console when WMI service is
stopped in MN.
When SCOM has discovered a Windows system displayed in the diagram
view, with the WMI service stopped on that system, the discovered
Windows system disappears from the SCOM console.
3
Dell alerts not getting sorted according to age
Check the registry on the machine that has this problem. There could be a
left over view definition that has the sorting flags set to 'false'. In some
instances, when you import an MP with changes to the sort flags, it may
not get updated in the registry. If you delete the settings for the view in the
registry, they will be recreated from the new MP when you navigate to that
view again. You can also edit the sort flags in the registry for the view.
Registry edit:
HKEY_CURRENT_USER\Software\Microsoft\Microsoft Operations
Manager\3.0\Console\%GUID.ViewTitle%AlertView\Age
For sorting to be enable ensure the keys IsSortable and IsSorted are
set to 1.