Release Notes
a) Right-click "Health Service Handle Count Threshold"
b) Select Overrides-> Override the Monitor-> For a Group
c) Choose "Management Server Computer Group"
d) Override the following parameters
* "Agent Performance Monitor Type - Threshold"
- "Override Setting" value from 2000 to 10000
* Enabled - "Override Setting" value to "true"
e) Apply the settings.
5. Select Entity Health-> Performance-> Health Service Performance
a) Right click "Health Service Private Bytes Threshold"
b) Select Overrides-> Override the Monitor-> For a Group
c) Choose "Management Server Computer Group"
d) Override the following parameters
* "Agent Performance Monitor Type - Threshold"
- "Override Setting" value from 104857600 to
1610612736
* Enabled - "Override Setting" value to "true"
e) Apply the settings.
9) The IPMI Power control and LED Identification tasks shipped with
the Dell Management Pack require BMU 2.0 or later to be installed on
the Operations Manager Management Server and have default BMC
credentials, and default path C:\Program Files\Dell\SysMgt\bmc
which cannot be modified.
If your systems have different BMC credentials, you need to install
BMU 2.0 on the Operator Console system and create new console tasks
in the authoring pane targeted on "BMC for Dell Server".
Select "Create new task" -> "Console Tasks - CommandLine" and set
the following command line parameters:
"Application:" Input the path of application "ipmish.exe"
(For example, c:\Program Files\Dell\SysMgt\bmc\ipmish.exe)
"Parameters:" for example:
-ip $Target/Property[Type="Dell.Connections00130025!Dell.Connections.
ServerBMC"]/BMCIPAddress$ -u %BMCUserName% -p %BMCPassword% -k
%BMCKGKey% %IPMITaskString%
The above BMCIPAddress string can be populated by selecting the drop
-down button indicating "BMC IP Address."
Update the BMC credentials - %BMCUserName%, %BMCPassword%, %BMCKGKey%
%IPMITaskString% - "power status" for CheckPowerStatus Task
- "power on" for PowerOn Task
- "power off" for PowerOffGrace Task
- "power off -force" for PowerOffForce Task
- "power cycle" for PowerCycle Task
- "power reset" for PowerReset Task
- "identify on" for LEDOn Task
- "identify off" for LEDOff Task
10) Operations Manager cannot discover DRAC inband on Dell PowerEdge
(TM) xx55 systems with modular chassis. Out of band is supported for
DRAC/MC and DRAC5 only.
11) Dell MP Diagram Views display blank screen intermittently. This
also happens when user does a screen refresh.
It is a Known Microsoft issue.