Release Notes

The latest web release is available at:
http://support.us.dell.com/support/downloads/format.aspx?releaseid
=R183698
* If the DRAC/CMC/Printer/iDRAC Console launch gives you a "Page
cannot be displayed" error, ensure that there is network connectivity
from the device (DRAC/CMC/Printer/iDRAC card), and that the device
is configured with a valid IP address.
* If attributes or hardware objects do not display for Dell Servers,
ensure that the CIM Dell namespace is not corrupted and that the Dell
Services are not down. Restart the Dell managed system or reinstall
Server Administrator to correct the CIM behavior.
* BMC Log reporting is supported only on IPMI 2.0 (or above)
compliant systems. BMC Reporting will not work on IPMI 1.5 systems
due to the dependency with the IPMI tool v2.0 which is used for
retrieving the Logs.
=====================================================================
Operations Manager Management Console Requirements
=====================================================================
NOTE: The Management Pack version 3.1 can be installed only on
Operations Manager 2007 SP1 and System Center Essentials 2007
SP1.
* Operations Console can be installed on Windows(TM) 2003, Windows
XP(TM) and Windows Vista(TM) operating systems.
* The Operations Manager 2007 SP1 agent software must be installed on
all Dell-managed systems either remotely from the management station
(Agent Push) or locally on the managed system.
* For discovered systems to be recognized as Dell Servers in the
Operations Manager 2007 SP1 environment, Server Administrator (5.3
or later) must be installed on all Dell-managed systems.
* For Out of band DRAC/CMC discovery, Network discovery of SNMPv1 and
SNMPv2 devices over the subnets must be performed in Operations
Manager administration.
* Dell Management Pack functions with a reduced feature set if the
Operations Manager 2007 SP1 Management Server Action account has
normal user privileges on all Dell managed systems.
NOTE: The Operations Manager 2007 SP1 Management Server Action
account needs administrator privileges on all Dell managed
systems to perform DRAC in-band object discovery and launch the
Dell Remote Access Console task. If the Management Server
Action account has normal user privileges, operators need to
provide task credentials with Power User (or higher) privileges
to run the Clear ESM Logs task, instead of selecting 'Use the
predefined Run as Account'.
* To run the Remote Power Control tasks or the LED Identification