Owner's Manual
162 Virtualization
ESXi Configuration
Enabling CIM OEM Providers
To receive the health information (reported in the Dell Management Console
monitor) from the ESXi server, enable the CimOemProvidersEnabled
configuration setting (set to value 1), and restart the Management Agents for
the first time after the ESXi installation.
To enable CIM OEM providers:
1
Download and install the RCLI tools from the VMware website at
vmware.com/go/remotecli/).
2
Run the following VmWare RCLI command from a remote Windows or
Linux server:
vicfg-advcfg.pl --server <ip_address> --username <user_name> --
password <password> --set 1 Misc.CimOemProvidersEnabled
3
Restart the Management Agents from the ESXi server Direct Console User
Interface (DCUI) menu or reboot the server.
NOTE: You can also set the CimOemProvidersEnabled property using VI Client
(Configuration
Software Advanced Settings Misc Enable OEM
Providers).
Dell Management Console Configuration
Secure Deployment Mode - Connecting to WSMAN over HTTPS
The following configurations are required in Dell Management Console to
connect to WS-MAN running in secure mode on the ESXi servers:
1
A WS-MAN credential set is created using Credential Manager.
Only one set of credentials is required if all of the ESXi servers have the
same username and password settings.
2
A connection profile with the WS-MAN protocol is enabled and the
following settings are applied:
a
The credential set is created as described in step 1.
b
The Secure mode is selected.
book.book Page 162 Monday, April 19, 2010 5:19 PM