Technical Guide
Table Of Contents
- Dell EMC PowerEdge T150 Technical Guide
- Contents
- System overview
- System features and generational comparison
- Chassis views and features
- Processor
- Memory subsystem
- Storage
- PCIe subsystem
- Power, thermal, and acoustics
- Supported operating systems
- Dell EMC OpenManage systems management
- Dell Technologies Services
- Dell EMC ProDeploy Enterprise Suite
- Dell EMC Remote Consulting Services
- Dell EMC Data Migration Service
- Dell EMC ProSupport Enterprise Suite
- Dell EMC ProSupport Plus for Enterprise
- Dell EMC ProSupport for Enterprise
- Dell EMC ProSupport One for Data Center
- ProSupport for HPC
- Support Technologies
- Dell Technologies Education Services
- Dell Technologies Consulting Services
- Dell EMC Managed Services
- Appendix A: Additional specifications
- Appendix B. Standards compliance
- Appendix C Additional resources
NIC port specifications
The PowerEdge T150 system supports up to two 10/100/1000 Mbps Network Interface Controller (NIC) ports embedded on
Motherboard.
Table 24. PowerEdge T150 NIC port specification
Feature Specification
LOM 1 GbE x 2
Environmental specifications
NOTE: For additional information about environmental certifications, refer to the Product Environmental Datasheet located
with the Documentation > Regulatory Information on www.dell.com/support/home.
Table 25. Operational climatic range category A2
Temperature Specifications
Allowable continuous operations
Temperature ranges for altitudes <= 900 m (<=
2953 ft)
10–35°C (50–95°F) with no direct sunlight on the equipment
Humidity percent ranges (non-condensing at all
times)
8% RH with -12°C minimum dew point to 80% RH with 21°C (69.8°F)
maximum dew point
Operational altitude de-rating Maximum temperature is reduced by 1°C/300 m (1.8°F/984 Ft) above 900
m (2953 Ft)
Table 26. Operational climatic range category A4
Temperature Specifications
Allowable continuous operations
Temperature ranges for altitudes <= 900 m (<=
2953 ft)
5–45°C (41–113°F) with no direct sunlight on the equipment
Humidity percent ranges (non-condensing at all
times)
8% RH with -12°C minimum dew point to 90% RH with 24°C (75.2°F)
maximum dew point
Operational altitude de-rating Maximum temperature is reduced by 1°C/125 m (33.8°F/410 Ft) above
900 m (2953 Ft)
Table 27. Shared requirements across all categories
Temperature Specifications
Allowable continuous operations
Maximum temperature gradient (applies to both
operation and non-operation)
20°C in an hour* (36°F in an hour) and 5°C in 15 minutes (9°F in 15
minutes), 5°C in an hour* (9°F in an hour) for tape
NOTE: * - Per ASHRAE thermal guidelines for tape hardware these are
not instantaneous rates of temperature change.
Non-operational temperature limits -40 to 65°C (-40 to 149°F)
Non-operational humidity limits 5% to 95% RH with 27°C (80.6°F) maximum dew point
Maximum non-operational altitude 12,000 meters (39,370 ft)
Maximum operational altitude 3,048 meters (10,000 ft)
42 Appendix A: Additional specifications