Technical Guide

Table Of Contents
Table 13. Power tools and technologies (continued)
Feature Description
Rack infrastructure Dell offers some of the industry's highest-efficiency power infrastructure solutions, including:
Power distribution units (PDUs)
Uninterruptible power supplies (UPSs)
Energy Smart containment rack enclosures
Find additional information at: https://www.delltechnologies.com/en-us/servers/power-and-
cooling.htm.
Power Supply Units
Energy Smart power supplies have intelligent features, such as the ability to dynamically optimize efficiency while maintaining
availability and redundancy. Also featured are enhanced power-consumption reduction technologies, such as high-efficiency
power conversion and advanced thermal-management techniques, and embedded power-management features, including high-
accuracy power monitoring. The table below shows the power supply unit options that are available for the T150.
Table 14. PowerEdge T150 PSU specifications
PSU Class Heat
dissipation
(maximum)
Frequency Voltage AC DC Current
High line
200240
V
Low line
100120 V
300 W AC Bronze 1024 BTU/
hr
50/60 Hz 100240 V
AC,
autoranging
300 W 300 W NA 4.6 A
400 W AC
(available
only from
Dec21)
Platinum 1365 BTU/
hr
50/60 Hz 100240 V
AC,
autoranging
400 W 400 W NA 5.4 A
NOTE: Heat dissipation is calculated using the PSU wattage rating.
NOTE: When selecting or upgrading the system configuration, to ensure optimum power utilization, verify the system
power consumption with the Dell Energy Smart Solution Advisor available at Dell.com/ESSA.
Thermal
PowerEdge servers have an extensive collection of sensors that automatically track thermal activity, which helps regulate
temperature thereby reducing server noise and power consumption.
Thermal design
Thermal management of the platform helps deliver high performance with the right amount of cooling to components, while
maintaining the lowest fan speeds possible. This is done across a wide range of ambient temperatures from 10°C to 35°C (50°F
to 95°F) and to extended ambient temperature ranges.
24